↓ Read PDF
01 · ABSTRACT

Abstract

Background: The clinical laboratory’s goal is to provide the right service at the right time with the best quality. It was observed that a scattered and complex workflow resulted in non-value-added activities and impacted turn around time. A shorter turnaround time was always in demand & discussion. After feedback from clinicians & the internal team, the laboratory took this project as a part of its Quality Improvement programme. A team from the laboratory & Process Excellence (PEx) Consultants from Ortho Clinical Diagnostics performed a workflow assessment to identify the root causes of delayed turnaround time. The team used the concept of ‘Lean’ which is a quality improvement tool that focuses on simplifying the process by removing the “waste” or “non-value added” activities.

Aim: This study aimed to use integrated solutions & Lean methodology to simplify the complex laboratory workflow.

Method: A pre and post intervention study was conducted using the DMAIC principle (Define, measure, analyze, improve & control). The intervention was an integrated platform for analysis of Biochemistry and Immunology samples. Laboratory Information System statistical analysis for turn around time, Operator tracking and Valustream mapping were used to identify the bottlenecks and eliminate non-value-added tasks. The laboratory turnaround time, number of vacutainers used, staff assigned to tasks, were compared in the pre-intervention (2019) & post-intervention (2022) period.

Results: The adoption of an integrated platform, helped reduce turnaround time for laboratory results by 26%. The integrated system also enhanced the capacity of the laboratory to handle the workload using lesser vacutainers saving US $ 2075 & US $ 30,000 per year from saving 43800 man-hours annually. The operator motion was reduced and 6 non-value-added steps were eliminated saving the laboratory 55 minutes per batch. Also, 100 sq.ft of space was saved which was utilized by the laboratory for other specialized testing.

Conclusion: Value stream mapping an important lean tool, helped the laboratory to identify bottlenecks at the pre-analytical stage due to non-value-added activities. Specific interventions like integration of the Clinical Chemistry & Immunology analyzer with central specimen receiving station the TAT compliance score improved by 41% and 6% for Biochemistry & Immunology assays respectively. The laboratory could also optimize their space, manpower and show potential savings of USD $ 32075/- per year. These measures improved the operational efficiency of the laboratory.

↓ Read PDF
02 · PUBLICATION RECORD

Article details

JournalMedical Research Archives
IssueVol 11 No 8 (2023): August Issue, Vol.11, Issue 8
SectionResearch Articles
Published05 September 2023
DOI10.18103/mra.v11i8.4323
ISSN2375-1924
03 · RIGHTS & REUSE

Rights & reuse

This article is published under a Creative Commons Attribution License (CC BY 3.0) and may be shared or distributed by anyone as long as attribution is given to the journal.

Authors & affiliations

AP

Aruna Poojary

Dept of Biochemistry & Microbiology, Breach Candy Hospital Trust, Mumbai, India

RC

Rittu Chaandel

Dept of Biochemistry & Microbiology, Breach Candy Hospital Trust, Mumbai, India

PJ

Parth Javale

Ortho Clinical Diagnostics (OCD)

KD

Kamal Dua

Ortho Clinical Diagnostics (OCD)

AB

Anurag Bari

Dept of Biochemistry & Microbiology, Breach Candy Hospital Trust, Mumbai, India

PP

Pritam Pardeshi

Dept of Biochemistry & Microbiology, Breach Candy Hospital Trust, Mumbai, India

SJ

Srushtee Jibhkate

Dept of Biochemistry & Microbiology, Breach Candy Hospital Trust, Mumbai, India

SR

Seema Rohra

Dept of Biochemistry & Microbiology, Breach Candy Hospital Trust, Mumbai, India

KK

K. Krishnan

Ortho Clinical Diagnostics (OCD)

Medical Research Archives

Submit your own article

Register as an author to reserve your spot in the next issue of the Medical Research Archives.

Start your submission  ↗