↓ Read PDF
01 · ABSTRACT

Abstract

This communication takes note of unexpected factors that can influence the results of RT-PCR in quantitation of copy numbers such as in determination of viral loads and in viral identification. We show that the presence of serum separator gel in authorized collection tubes for hepatitis C (HCV) viral load determinations causes underestimation of viral loads by blocking viral diffusion into plasma and that the presence of more than one targeted virus in a multiplex RT-PCR viral assay, while not affecting analytical specificity, results in raising of the minimal detectable viral titer and therefore a decreased analytical sensitivity. Our results suggest the possibility that HCV samples should be placed in cell lysis buffer for full viral load determination and that multiplex assays should be carefully validated and modified if necessary to minimize loss of sensitivity.

↓ Read PDF
02 · PUBLICATION RECORD

Article details

JournalMedical Research Archives
IssueVol 12 No 5 (2024): MAY ISSUE, Issue 5, VOl.12
SectionResearch Articles
Published26 May 2024
DOI10.18103/mra.v12i5.5285
ISSN2375-1924
03 · RIGHTS & REUSE

Rights & reuse

This article is published under a Creative Commons Attribution License (CC BY 3.0) and may be shared or distributed by anyone as long as attribution is given to the journal.

Authors & affiliations

HC

HuiTing Cheng

Department of Cell Biology, SUNY Downstate Medical Center 450 Clarkson, Avenue, Brooklyn, NY 11203.;  Miriums Laboratories, 760 Parkside Avenue. Brooklyn, NY 11203.

PP

Prem Premsrirut

Department of Cell Biology, SUNY Downstate Medical Center 450 Clarkson, Avenue, Brooklyn, NY 11203.;  Miriums Laboratories, 760 Parkside Avenue. Brooklyn, NY 11203.

LT

Lilly Tennyson

Department of Cell Biology, SUNY Downstate Medical Center 450 Clarkson, Avenue, Brooklyn, NY 11203.;  Miriums Laboratories, 760 Parkside Avenue. Brooklyn, NY 11203.

PM

Philip Mo

Department of Cell Biology, SUNY Downstate Medical Center 450 Clarkson, Avenue, Brooklyn, NY 11203.;  Miriums Laboratories, 760 Parkside Avenue. Brooklyn, NY 11203.

XW

XiaoHong Wang

Veterans Affairs New York Harbor Healthcare System - Manhattan Campus

MS

Miriam Silberstein

Department of Pathology, SUNY Downstate Medical Center, 450 Clarkson Avenue, Brooklyn, NY 11203.

MP

Matthew R. Pincus

Miriums Laboratories, 760 Parkside Avenue. Brooklyn, NY 11203; Department of Pathology, SUNY Downstate Medical Center, 450 Clarkson Avenue, Brooklyn, NY 11203.

Medical Research Archives

Submit your own article

Register as an author to reserve your spot in the next issue of the Medical Research Archives.

Start your submission  ↗